Air conditioning
Mercedes Sprinter: tracing an air-conditioning leak
Mercedes-Benz Sprinter 316 CDI
When a Sprinter’s air conditioning stopped blowing cold after an earlier regas, the owner returned to Vulcan Motors for an investigation. The technician found signs of a leak at an expansion valve.
View the illustration ↓
When cooling stopped
The customer reported that the air conditioning was no longer blowing cold after an earlier regas. The workshop investigated the system rather than assuming a further recharge would address the cause.
Looking for the leak
The technician recorded that no refrigerant was recovered during the check. Soapy-water testing produced bubbles around the expansion valve, indicating a leak there. The technician also noted that other leaks could still be present.
The repair recorded
At a subsequent visit, the invoiced job records removal and installation of the rear expansion valve, with a replacement valve and seals listed as fitted. The notes reviewed do not establish a final leak-free test or cooling result.
Why an investigation helps
Poor cooling can have several causes, including a loss of refrigerant or a fault in another component. Identifying the issue helps the workshop discuss suitable repairs for the particular vehicle.
Speak to the team
If your vehicle’s air conditioning is not cooling as expected, tell reception what you have noticed and whether the system has recently been serviced. The team can arrange an assessment.
Explore your options
The services behind this story.
Something similar in mind?
Tell us about your vehicle and what you need. We will discuss the assessment, compatibility and agreed scope for your own project.